VRLA · AGM · Gel · 12V & 2V Cells

Leoch Batteries — VRLA AGM UPS Batteries

Leoch VRLA AGM and Gel batteries for UPS, telecom, solar, and emergency lighting applications. 12V monobloc batteries from 7Ah to 200Ah, and 2V cells for high-capacity strings. Sukhai UPS supplies and installs Leoch batteries across Thane, Mumbai, Pune, and Maharashtra. Call +91-98208-43000 for a battery sizing consultation.

Call +91-98208-43000
25+
Years of Experience
5,000+
Clients Served
50+
Cities Covered
4.9★
Average Rating
About the Brand

About Leoch Battery

Leoch International Technology is a Chinese battery manufacturer founded in 1999, specialising in valve-regulated lead-acid (VRLA) batteries for a wide range of standby and cyclic power applications.

VRLA Technology

Leoch batteries are sealed valve-regulated lead-acid (VRLA) batteries, meaning there is no free liquid electrolyte and the battery requires no topping up with water. The valve-regulated design recombines the hydrogen and oxygen produced during charging back into water, making these batteries safe for use indoors in UPS rooms, server rooms, and equipment enclosures without special ventilation requirements beyond general air circulation.

AGM & Gel Variants

Leoch manufactures both AGM (absorbed glass mat) and Gel battery types within the VRLA category. AGM batteries use a fibreglass mat separator saturated with electrolyte, which delivers high discharge rates and low internal resistance — well suited to UPS applications where short, high-current discharge events are typical. Gel batteries use a silica-thickened electrolyte that is more tolerant of deep discharge and elevated operating temperatures, making them suitable for solar and telecom cycling applications.

Capacity Range

The Leoch range covers 12V monobloc batteries from 7Ah to 200Ah, addressing UPS systems from small office units upward. For large-capacity battery strings in data centres and telecom infrastructure, Leoch also manufactures 2V single cells available in capacities from 100Ah to 3,000Ah per cell. These 2V cells are connected in series strings — twelve 2V cells make a 24V system, twenty-four cells make a 48V string, and so on — to build the required system voltage at any desired capacity.

Product Series

Leoch Battery Series

Leoch offers distinct battery series tailored to different application requirements — from standard UPS standby to deep-cycle renewable energy storage and large-capacity telecom strings.

Leoch DJW Series — 12V AGM

The DJW series is Leoch's standard VRLA AGM range, covering 7Ah to 200Ah at 12V. These batteries are designed for general-purpose standby applications including office UPS systems, home inverters, and commercial power backup. The DJW series balances cost and performance, offering a stable float voltage, low self-discharge, and reliable standby life under normal indoor operating conditions.

  • Capacity: 7Ah to 200Ah (12V)
  • Technology: AGM, sealed VRLA
  • Applications: office UPS, commercial backup
  • Maintenance-free, no topping up required

Leoch LP / LPX Series — 12V AGM High-Rate

The LP and LPX series are optimised for high-rate discharge — delivering more power per unit of capacity in the short-duration, high-load discharge events typical of UPS applications. These batteries have lower internal resistance and are engineered to maintain a higher voltage under heavy load, which translates to more usable runtime at high power. The LPX series is particularly suited to IT and data centre UPS applications where the load is predominantly computing hardware.

  • High-rate discharge optimised
  • Lower internal resistance than standard AGM
  • Suitable for IT loads and server rooms
  • 12V, range of Ah ratings

Leoch DJM Series — 12V Gel

The DJM series uses gel electrolyte technology, providing better deep-discharge recovery and improved performance in applications with regular charge-discharge cycling. Gel batteries are more tolerant of partial state of charge and elevated operating temperatures compared to AGM, making the DJM series the preferred choice for solar energy storage systems, remote telecom base stations, and other cycling applications where the battery may regularly reach a low state of charge before being recharged.

  • Gel electrolyte — better cycle performance
  • Improved deep-discharge recovery
  • Suited to solar and telecom applications
  • 12V monobloc configuration

Leoch LPC Series — 2V Cells

The LPC series consists of 2V single cells for constructing large-capacity battery strings in data centres, telecom exchanges, and industrial UPS installations. Individual cells are available from 100Ah to 3,000Ah, allowing system designers to build any required combination of voltage and total energy. 2V cell strings are the standard approach for large online UPS battery cabinets and central battery systems where high total capacity is needed in a space-efficient, serviceable format.

  • 2V cells: 100Ah to 3,000Ah per cell
  • Series-connected to any required voltage
  • Data centre and telecom infrastructure
  • Individually replaceable cells
Technical Data

Technical Specifications Overview

The following specifications represent the general characteristics of Leoch VRLA UPS batteries. Refer to the specific model datasheet for exact figures, as values vary by series and capacity.

Nominal Voltage

12V for monobloc batteries (DJW, LP/LPX, DJM series). 2V for individual cells (LPC series). Multi-cell strings are connected in series to achieve 24V, 48V, or higher system voltages as required by the UPS.

Design Life

Typically 5–10 years at 20°C, depending on the series. Design life is a manufacturer rating under controlled float conditions; actual service life will vary based on operating temperature, depth of discharge, and charge-discharge cycle frequency. Elevated temperatures reduce life significantly — every 10°C above 25°C approximately halves battery life.

Operating Temperature

Charge: -15°C to +50°C. Discharge: -15°C to +45°C. Recommended storage and operating environment for maximum life is 20–25°C. Batteries stored or operated consistently above 30°C will experience accelerated capacity loss and reduced service life.

Electrolyte Type

Electrolyte is fully immobilised — absorbed in the AGM separator (AGM series) or in a silica gel matrix (Gel series). There is no free liquid electrolyte. Batteries can be operated and stored in any orientation (upright or on their side) without risk of leakage. No periodic water addition or electrolyte servicing is required during the service life of the battery.

Self-Discharge Rate

Approximately 3% per month at 20°C. Batteries can typically be stored for 6 months without recharging under ideal conditions. For longer storage, a refresher charge is recommended. Self-discharge rate increases with temperature — batteries stored in warm environments will need more frequent maintenance charging to prevent sulfation and capacity loss.

Maintenance Requirements

Leoch VRLA batteries are maintenance-free under normal UPS float operation. There is no requirement to check electrolyte levels, add water, or equalise cells individually. Periodic capacity testing (load bank or discharge test) is recommended annually after the third year of service to assess remaining capacity and identify batteries approaching end of life before they cause a backup failure.

Applications

Applications of Leoch Batteries

Leoch VRLA batteries serve a broad range of standby and cyclic power applications across commercial, industrial, and infrastructure sectors.

UPS Systems

Leoch VRLA batteries are used in UPS systems ranging from 500VA home units to large-capacity data centre UPS strings. AGM models in the DJW and LP/LPX series are particularly well suited to the high-rate, short-duration discharge profile of UPS applications, delivering rated capacity reliably during power outages across the installed capacity range.

Telecom & BTS

Mobile base transceiver stations (BTS) in remote or rural areas depend on reliable battery backup during grid outages. Leoch VRLA batteries — both AGM and Gel variants — are used extensively in telecom backup applications. The wide operating temperature range and low self-discharge make them suitable for outdoor equipment cabinets and poorly climate-controlled BTS sites where temperature control is limited.

Solar Energy Storage

The DJM gel series is suited to solar photovoltaic energy storage systems where the battery undergoes regular deep charge-discharge cycling. Gel technology handles the partial state of charge conditions common in solar applications — where the battery may not always be fully charged before discharge begins — with better tolerance than AGM. Suitable for off-grid solar installations and hybrid solar backup systems.

Emergency Lighting

VRLA batteries are the standard power source for central battery emergency lighting systems in commercial and industrial buildings. Leoch VRLA batteries offer a low-maintenance, long standby life suitable for central battery units powering emergency exit signs, escape route luminaires, and safety lighting systems. The sealed, maintenance-free design is an advantage in ceiling voids and distribution boards where periodic maintenance access is difficult.

Supply & Installation

Battery Replacement & Supply

Sukhai UPS supplies and installs Leoch batteries as replacements in existing UPS systems and as batteries for new UPS installations across Maharashtra.

On-Site Replacement Service

Our engineers carry out battery replacements on-site at your premises, covering Thane, Mumbai, Navi Mumbai, Pune, and surrounding Maharashtra cities. We handle the full replacement process — removing old batteries, installing new Leoch batteries, checking UPS float voltage and charging parameters, and disposing of the old batteries in compliance with applicable regulations. Contact us at +91-98208-43000 to schedule an inspection.

Backup Time & Sizing

Battery backup time depends on three factors: total battery capacity in ampere-hours (Ah), the connected load in watts (W), and the inverter or UPS efficiency. A higher Ah rating provides longer backup; a higher load reduces backup time. For example, a 100Ah battery at 12V theoretically stores 1,200Wh — but practical backup time at load will be less due to battery discharge efficiency and inverter losses. We recommend a proper battery sizing assessment before selecting a replacement to ensure the new battery meets your backup time requirement.

Cross-Brand Compatibility

Leoch VRLA batteries are compatible with UPS systems from all major brands including APC, Eaton, Emerson Vertiv, Numeric, and Delta. The critical requirement is matching the voltage (12V or 2V cell) and capacity (Ah) to the original battery specification of your UPS. We confirm compatibility before supply to ensure the replacement battery integrates correctly with your existing UPS charging system and meets your backup time requirements.

FAQ

Leoch Batteries — Frequently Asked Questions

Leoch AGM batteries use a glass mat separator to hold the electrolyte, offering high discharge rates and good cycle life. Gel batteries use a silica-based gelled electrolyte that provides better deep-discharge recovery and performance in high-temperature or cycling applications like solar storage. For standard UPS standby use, AGM is typically the appropriate choice; for solar, remote telecom, or cycling applications, Gel is preferred.
Leoch VRLA batteries have a design life of 5–10 years depending on the series. Actual service life depends on operating temperature, depth of discharge, and number of charge-discharge cycles. High temperatures shorten battery life significantly — a battery operating at 30°C continuously will reach end of life noticeably sooner than the same battery at 20°C. Annual capacity testing after the third year of operation is a practical way to track remaining battery health.
Signs include: battery not holding charge, UPS switching to battery even during minor fluctuations, the UPS alarm sounding persistently, or the battery being more than 3–5 years old. Physical signs such as a swollen or bulging battery case indicate the battery has failed and must be replaced immediately. A battery load test — where the battery is discharged under a known load and runtime measured — gives a definitive answer about remaining capacity.
Yes. Leoch VRLA batteries are compatible with all major UPS brands including APC, Eaton, Emerson Vertiv, Numeric, and Delta, provided the voltage and Ah rating match the UPS battery specification. VRLA batteries from different manufacturers share standardised voltage and charging characteristics, so a correctly rated Leoch battery can be used as a direct replacement in any UPS that uses a 12V VRLA battery of the same Ah capacity.
Yes. Sukhai UPS provides on-site battery replacement services across Thane, Mumbai, Navi Mumbai, Pune, and surrounding Maharashtra cities. Our engineers carry out the complete replacement including removing old batteries, installing new Leoch batteries, verifying UPS charging voltage, and arranging responsible disposal of the used batteries. Contact +91-98208-43000 to schedule a battery inspection or replacement visit.
Related Products & Services

Explore Related Battery Solutions

All Batteries

Browse the full range of UPS battery solutions — SMF/VRLA, lithium-ion, tubular, and battery banks — available from Sukhai UPS.

View All Batteries →

SMF / VRLA Batteries

Overview of sealed maintenance-free VRLA battery technology and the full range of VRLA batteries available for UPS systems.

View SMF / VRLA Batteries →

Battery Banks

Extended battery bank solutions for longer UPS runtime — custom configurations for data centres, server rooms, and industrial UPS.

View Battery Banks →

UPS Battery Replacement

On-site battery replacement service for all UPS brands across Maharashtra — inspection, sizing, supply, installation, and disposal.

View Battery Replacement →

Exide Batteries

Exide VRLA batteries for UPS systems — a leading Indian brand with a wide range of SMF and tubular batteries across Ah ratings.

View Exide Batteries →

Quanta Batteries

Quanta VRLA batteries — widely used in APC, Eaton, and Emerson UPS systems across data centre and commercial applications.

View Quanta Batteries →

APC UPS

APC by Schneider Electric online and line-interactive UPS systems — from 500VA desktop units to 500 kVA data centre systems.

View APC UPS →

Get a Quote for Leoch Batteries

Tell us your UPS model, current battery rating (voltage and Ah), and location — we will confirm the correct Leoch replacement battery, provide a quote, and arrange on-site installation at your premises in Thane, Mumbai, Navi Mumbai, Pune, or anywhere in Maharashtra.