Sukhai UPS supplies genuine SMF (Sealed Maintenance Free) VRLA batteries from 7Ah to 200Ah across India. 12V batteries for online UPS, offline UPS, telecom, solar, and emergency backup. Brands available: Exide, Quanta (Amara Raja), Amaron, Leoch, and Panasonic. Call for same-week delivery.
Understanding Sealed Maintenance Free (VRLA) battery technology — why it dominates UPS applications in India.
SMF batteries are completely sealed — no access to electrolyte, no water topping required. The electrolyte is immobilized in a glass mat (AGM) or gelled (Gel VRLA), making the battery spill-proof and safe for indoor use. This is why all commercial UPS systems use SMF VRLA batteries.
VRLA stands for Valve Regulated Lead Acid. A one-way pressure-relief valve vents excess gas if the battery is overcharged, preventing rupture. During normal operation (float charging), the oxygen generated at the positive plate recombines internally with hydrogen at the negative plate — a process called oxygen recombination — keeping water loss near zero.
Most UPS SMF batteries are AGM (Absorbent Glass Mat) type — the electrolyte is absorbed into glass fibre separators, giving fast charge acceptance and high discharge rates. Gel VRLA uses silica to gel the electrolyte; it handles deep discharge and high temperature better, making it suitable for solar backup. For standard UPS applications, AGM is the standard choice.
All standard SMF VRLA batteries for UPS use are 12V nominal. Capacity is specified in Ampere-hours (Ah) at the 20-hour rate (C20).
Used in small desktop and tower UPS (500VA–1 kVA). Typical internal battery in APC Back-UPS, Numeric, Microtek, and Luminous UPS. Usually 2 batteries in series = 24V string.
Used in 2–3 kVA online UPS with extended backup. Standalone external battery packs for single-phase UPS. Commonly stacked in 2–4 unit strings.
Used in 5–10 kVA UPS systems. External battery cabinets for single-phase and 3-phase UPS. Provides 15–30 minutes backup at full load for typical data centre edge setups.
Used in large 3-phase UPS (20–100 kVA) battery banks. Multiple parallel strings for extended backup. 200Ah batteries typically require floor-standing battery cabinets due to weight (approx. 60–65 kg per unit).
Battery string calculation: (1) Determine UPS DC bus voltage (typically 192V, 240V, or 384V for 3-phase UPS). (2) Divide by 12V to get number of batteries in series per string. (3) Calculate required Ah using: Ah = (Load × Backup Time) / (DC Voltage × Efficiency × 0.8 DoD). (4) Divide by selected battery Ah rating and round up for number of parallel strings. Contact Sukhai UPS for a free battery sizing calculation for your specific UPS model.
We stock genuine batteries from India's most trusted SMF VRLA brands. All products are sourced through established distribution channels with valid manufacturer warranty.
India's largest battery manufacturer. The Powersafe series (EL, ELX, EP) covers 7Ah to 200Ah in 12V. Widely used as OEM batteries in APC and Eaton UPS systems. BIS certified, ISO 9001 manufacturing.
View Exide Batteries →Quanta is Amara Raja's industrial and telecom VRLA brand. Extensively used in Airtel, BSNL telecom infrastructure and enterprise UPS. AGM technology, low self-discharge, wide temperature range.
View Quanta Batteries →Japanese-manufactured LC-P series batteries are known for exceptional cell-to-cell consistency and long float service life. Preferred for critical applications like hospitals and financial data centres.
View Panasonic Batteries →SMF VRLA batteries are the universal power backup solution across industries — anywhere a sealed, maintenance-free battery is required.
The primary application. All double-conversion online UPS (APC, Eaton, Emerson) use SMF VRLA batteries in internal or external battery banks. The sealed design prevents gas accumulation in server rooms and equipment rooms.
View Online UPS →Telecom base transceiver stations (BTS) use large VRLA battery banks (100Ah–200Ah) as backup power for 2–4 hour runtime. BSNL, Airtel, and Jio towers across India predominantly use Quanta and Exide SMF batteries.
SMF AGM batteries are used in small-to-medium solar backup systems where maintenance access is limited. For daily deep cycling in large solar installations, Gel VRLA or lithium-ion is preferred. Consult us for the right battery technology for your solar application.
Compare Li-ion for Solar →Small 7Ah and 12Ah SMF batteries power emergency lighting systems, exit signs, and fire alarm panels. The sealed design meets building safety code requirements for indoor installations.
CCTV systems, access control panels, intruder alarm systems, and video surveillance use 7Ah–26Ah SMF batteries as standby power. The compact sealed design fits within control panels without ventilation concerns.
Office and home offline UPS (650VA–3 kVA) use internal SMF batteries (7Ah–26Ah) for short backup times of 10–30 minutes. These batteries are replaceable and are a common battery replacement service we offer.
Battery Replacement Service →Understanding VRLA battery lifespan — and how to know when it's time to replace your UPS batteries.
Standard SMF VRLA batteries have a design life of 3–5 years at 25°C (float service). The battery is typically replaced when capacity falls below 80% of its rated Ah value. High-end batteries (Panasonic, specific Exide series) may have 5–10 year design life at reduced float voltage.
Battery life halves for every 8–10°C rise above 25°C. At 35°C (common in Indian UPS rooms without adequate cooling), a 5-year design life battery may last only 2.5 years. Keep UPS battery rooms air-conditioned at 20–25°C for maximum battery life.
Key indicators: (1) Backup time reduced to less than 50% of original. (2) Battery fault or replace battery LED on UPS. (3) Physical swelling or bulging of battery case. (4) Battery age over 4 years. (5) Failed impedance test during PM — high internal resistance indicates sulfation. Schedule a battery health check with us.
Plan battery replacement proactively — at 3–4 years for most SMF VRLA. Replacing batteries before failure avoids unplanned downtime. Sukhai UPS offers battery health testing, right-size replacement selection, installation, and old battery recycling as a complete service.
LiFePO4 battery solutions offering 8–15 year life, 60% lighter weight, and 4× faster charging vs VRLA. Ideal for data centre UPS upgrades.
View Li-ion Batteries →Flooded tubular batteries for home inverters and solar backup. Exide, Luminous, Amaron. 100Ah–200Ah. Better deep-cycle life than flat-plate batteries.
View Tubular Batteries →Professional on-site battery replacement for all UPS brands. Exide, Quanta, Amaron, Leoch, Panasonic. Old battery disposal included. 24–48hr delivery.
Battery Replacement Service →Custom VRLA battery bank design, supply, and installation for 10 kVA to 500 kVA UPS systems. String calculations, cabinet supply, and commissioning.
View Battery Banks →Impedance-based battery health testing for VRLA batteries. Identifies failing cells before they cause downtime. Recommended annually for data centre battery banks.
Battery Testing Service →Exide battery supply — Powersafe SMF VRLA (7Ah–200Ah) and Inva Tubular inverter batteries. India's largest battery manufacturer. BIS certified.
View Exide Range →