All Brands — On-site & Depot Repair — 30-Day Warranty

UPS Repair Services — Expert On-site & Depot Repair for All Brands

When your UPS fails, every minute counts. Sukhai UPS provides fast, expert repair for all UPS brands and capacities — from 500VA desktop units to 500 kVA 3-phase industrial systems. Component-level diagnosis, genuine OEM parts, 30-day repair warranty, and 24/7 support for critical customers. Call now for immediate assistance.

Call +91-98208-43000
25+
Years of Experience
5,000+
Clients Served
50+
Cities Covered
4.9★
Average Rating
Fault Coverage

What We Repair

Sukhai UPS engineers are trained to diagnose and repair the full range of UPS faults — from simple component failures to complex board-level and power electronics faults in both single-phase and 3-phase systems.

A UPS system comprises multiple subsystems — the rectifier/charger, the inverter, the static bypass switch, the control/DSP board, and the battery system. Faults can occur in any of these areas, often presenting as alarm conditions, failure to switch to battery, noisy output, or complete shutdown. Our engineers carry diagnostic equipment to identify the precise fault down to the component level.

Common UPS faults we repair include:

Rectifier & Charger Failure

Failed input rectifier diodes, SCRs, IGBTs, or PWM controller faults causing the UPS to fail to charge the battery or fail to pass mains power to output.

Inverter Failure

IGBT module failure, gate driver faults, DC link capacitor failure, or inverter control card faults causing the UPS to fail to deliver AC output from battery.

Control Card & DSP Failure

Microprocessor, DSP, or FPGA faults on the main control PCB causing display errors, communication failures, incorrect alarm conditions, or erratic behaviour.

Bypass Switch Failure

Static bypass SCR failure, manual bypass contactor faults, or bypass control logic errors leaving the load unprotected or preventing bypass activation.

Battery Charger Faults

Overcharging, undercharging, or charger shutdown faults that damage batteries or leave them discharged. We repair charger stages and replace failed components.

Fan, Filter & Cooling Faults

Fan failure leading to thermal shutdown, clogged air filters causing overheating, thermal sensors and protection circuit faults — all repaired and components replaced.

How It Works

Our UPS Repair Process

A structured, transparent repair process from the moment you call to the moment your UPS is back in service — with no surprises.

Step 1 — Emergency Call & Remote Diagnosis

Call or WhatsApp us with the fault symptoms, UPS model, and any alarm codes displayed. Our engineers begin remote diagnosis immediately — often narrowing down the fault type before anyone arrives on site.

Step 2 — On-site Engineer Dispatch

An engineer is dispatched to your site with diagnostic tools and common spare parts. Metro city response within 4–8 hours for AMC customers; next business day for non-AMC customers (emergency response also available).

Step 3 — Component-Level Diagnosis

Full diagnostic of rectifier, inverter, control card, bypass, and battery system using UPS manufacturer diagnostic software and electronic test equipment. Fault is identified down to the component or PCB level.

Step 4 — Genuine OEM Part Sourcing

Required spare parts are sourced as genuine OEM components from authorised distributors. You receive a repair estimate detailing parts and labour cost before we proceed — no work is done without your approval.

Step 5 — Repair & Full System Test

Fault is repaired and all UPS subsystems are verified — input voltage, output voltage, transfer time, battery charging, bypass function, and runtime under load. UPS is confirmed operational before we leave.

Step 6 — Handover & 30-Day Warranty

You receive a detailed repair report documenting the fault found, parts replaced, and test results. All repair work is covered by a 30-day warranty. We also recommend an AMC plan to prevent future unplanned failures.

Multi-Brand Repair

UPS Brands We Repair

Our engineers are factory-trained on the leading UPS platforms and experienced on a wide range of commercial and industrial UPS systems across all capacities.

APC Smart-UPS, Galaxy 3500, Easy-UPS 3S
Eaton 5PX, 9PX, 93PM, 9395P
Emerson Vertiv Liebert GXT5, EXL, Hipulse-U
BPE All single & 3-phase models
Numeric / Legrand iTrust, Keor LP, Keor S
Delta Amplon N, Ultron HPH
Hitachi Hi-UPS, TU Series
Luminous All UPS models
Microtek All UPS models
Socomec Netys, Masterys IP+
Repair Options

On-site Repair vs Depot Repair

The right repair approach depends on the size, weight, and complexity of the fault in your UPS system. We use the most appropriate method to minimise downtime.

On-site Repair (10 kVA and above)

For medium and large 3-phase UPS systems (typically 10 kVA and above), on-site repair is the standard approach. These systems are rack-mounted, cabinet-sized, or floor-standing units that cannot be practically transported. Our engineers visit your site with all necessary tools, test equipment, and commonly required spare parts. Module swaps on modular UPS systems are always completed on-site with zero downtime if redundant modules are available.

Depot Repair (Under 10 kVA)

For smaller single-phase UPS systems (typically under 10 kVA), depot repair often provides faster turnaround and allows board-level component repair using specialised soldering stations, component analysers, and bench test equipment. Units are collected from your site, repaired at our workshop, fully tested, and returned. We can provide a loan unit during depot repair for critical applications.

Hybrid On-site / Board-Level

For situations where the UPS must remain on-site but requires board-level repair, we remove the specific PCB or module for depot repair while the main UPS chassis remains installed. This minimises the period your load is unprotected and avoids the logistics of moving large systems.

Emergency Replacement Provision

When a repair will take longer than acceptable, we can supply a temporary replacement UPS from our rental fleet to protect your load while the original unit is being repaired. UPS on rent is available for 1 kVA to 60 kVA systems.

Emergency Service

Emergency UPS Repair Response

UPS failures don't follow business hours. Our emergency repair response capability ensures you're never left without support when it matters most.

Response Times

AMC customers in Mumbai, Thane, Navi Mumbai, and Pune receive 4–8 hour emergency response. Priority CMC customers receive 2–4 hour response. Non-AMC customers receive next business day response (emergency same-day available on request).

WhatsApp Support

Send fault images, alarm screenshots, and UPS model photos via WhatsApp to +91-98208-43000. Our engineers can often diagnose the fault from alarm codes and confirm parts availability before arriving on site — saving time.

24/7 for Critical AMC Customers

Hospitals, data centres, and banking customers on critical CMC plans receive 24/7 on-call engineer support. After-hours emergency response is available as an add-on to standard AMC contracts for any customer with critical power protection needs.

FAQ

UPS Repair — Common Questions

Yes. Sukhai UPS repairs all major UPS brands including APC, Eaton, Emerson Vertiv, BPE, Numeric (Legrand), Delta, Hitachi, Luminous, Microtek, and Socomec. Our engineers are trained on single-phase and 3-phase UPS systems across all capacities from 500VA to 500kVA.
For common faults such as fan failure, fuse replacement, or battery charger issues, same-day or next-day repair is typically possible. For complex faults requiring component-level board repair or sourcing of specialised parts, turnaround is usually 3 to 7 business days. We provide an estimated repair time and cost before proceeding.
Yes. All spare parts used in our UPS repairs are genuine OEM components sourced from authorised distributors. We do not use counterfeit or low-quality aftermarket parts. Using genuine parts ensures the repaired UPS performs to its original specifications and your warranty or AMC coverage is not voided.
All UPS repair work carried out by Sukhai UPS comes with a 30-day repair warranty covering the specific fault that was repaired. If the same fault recurs within 30 days, we will re-attend and rectify at no additional charge. Parts replaced also carry the standard manufacturer warranty.
Yes. For 3-phase industrial UPS systems of 10kVA and above, on-site repair is our standard approach as these systems are too large and heavy to transport. Our engineers carry diagnostic tools and common spare parts for on-site fault resolution. For board-level repairs requiring specialised equipment, the specific PCB or module may be taken to our depot while the main UPS remains in place.
Related Services

Related UPS Services

UPS AMC Services

Prevent breakdowns with a structured Annual Maintenance Contract. All brands, 4–8 hour emergency response, genuine parts at pre-agreed rates.

View AMC Services →

UPS Battery Testing

Battery failure causes 60% of UPS faults. Impedance and discharge load testing predicts battery end-of-life before it causes a system failure.

View Battery Testing →

UPS Preventive Maintenance

Scheduled PM visits to inspect, clean, and test your UPS before faults develop. Full service report with recommendations after every visit.

View PM Services →

Also see: UPS Installation  |  APC UPS  |  Eaton UPS  |  Emerson UPS  |  BPE UPS  |  Numeric UPS  |  UPS Dealers Mumbai  |  UPS Dealers Thane

UPS Not Working? Call Us Now

Describe your UPS fault on WhatsApp with photos of the display and any alarm codes. Our engineer will respond immediately with a diagnosis and repair plan.